PARAMETER
DEFAULT
DESCRIPTION
P101 Transducer
2 = dB6
Type of transducer being used
P102 Material
1 = Liquid
Material in the vessel, either liquid or
solid. If the solid lays flat, then it can
be entered as liquid.
P104
Measurement Units
4 = feet
Select units to be used for
programming measurement
information.
P105
Empty Level
19.685 feet
Distance from the face of the
transducer to the material at the
bottom of the vessel.
P106 Span
18.701 feet
Distance from the empty level (0%
full) to span (100% full).
PARAMETER
DEFAULT
DESCRIPTION
P600
Vessel Shape
0=Cyl. Flat
Base
Shape of vessel being monitored.
P601-P603
Vessel Dimensions
Dependent
on vessel
shape
selected.
Enter Vessel dimensions as required
P605
Volume units
7 = Cubic ft
Selects volume units required.
P607
Max Volume
Read Only
Displays the calculated Volume in
P605 units.