PULSAR MEASUREMENT
59
This will operate as follows, when the level rises on the upstream side and/or
the level on the downstream side falls, resulting in a differential of 0.5 feet,
(anywhere within the working span), indicating that the screen is blocked,
relay 1 will come on and operate the rake. Once the level on the inflow has
decreased and the differential level falls to 0.1 feet relay 1 will switch off the
rake.
Should the level on the upstream side rise, for any reason, to a level of 8.5
feet, relay 2 will operate to give a high alarm, once the level has fallen back
to 8.0 feet the alarm will go off. A falling level in the downstream side, for
any reason, will operate relay 3 at 1.0 feet giving an alarm for low level, once
the level has risen again to a value of 1.5 feet m relay 3 will reset.
To program the UltraTWIN for
Example 4 Differential Control
by using the
Quick Setup
menu proceed as follows. Access the
Program Mode and
key
in the
passcode
1997
and press
ENTER
. At the
Quick Setup
menu press
ENTER
and as prompted, by the questions, select the relevant option and
ENTER
.
QUESTION
OPTION
Level/Pump /Flow
1 = Level/Vol
Level or Volume
1 = Level
Control
1 = Control Down
No. of Control relays
1 = 1 Control
Control No. 1
1 = Set to Relay 1
No. of alarms
1 = 1 Alarm
Type Alarm 1
1 = High Alarm
Alarm No. 1
Set to Relay 2
Xducer (P*101)
2 = dB6
Material (P*102)
1 = Liquid
Measurement units (P*104)
4 = feet
Empty Level (P*105)
11.0 feet
Span (P*106)
10.0 feet
Press
CANCEL
to come out of the
Quick setup
menu for point 1 and press
the hotkey to switch to point 2.
At the
Quick Setup
menu for point 2 press
ENTER
and as prompted by the
questions, select the relevant option, and
ENTER
.