To set-up an application for a device contained in
special
, choose
3
for
Flow
followed by
5
for
Special
. You then need to select the
primary measuring
device
for your application from the following available options:
Palmer
Bowlus flume
,
H-flume
or a
V notch,
other than BS3680.
For devices, which do not match any of the above devices the application
can be setup using a
universal flow calculation
, to select this option
choose
3
for
Flow
followed by
6
for
universal
. You then need to select the
primary measuring device
for your application from the following available
options:
linear flow
or
curved flow.
Once you have chosen your application you will be asked a series of
questions which are answered by choosing the appropriate option as
detailed in the flow chart below. Once all the questions have been answered
you will be prompted to provide further information, as detailed in the
tables below, to complete the programming of the unit.