Cable Entry
There are 6 cable gland knockouts on the base of the wall mount UltraTWIN
(5 x M20, 1 x M16) and 4 on the rear (4 x 18mm dia (PG11)). Select which
ones you wish to take out, and remove them by using a circular cutter, such
as a tank cutter. Take care not to damage the circuit board inside whilst
undertaking this. Do not use a hammer, as this may cause damage to the
enclosure.
It is recommended that you use suitable cable glands to ensure that the
ingress rating is maintained and that they be tightened to the manufacturers
recommended settings.
Fascia Mount
The dimensions of the wall fixing holes are as shown below:
Important Information
All cable glands should be tightened to the m
anufacturer’s specifications.
The terminal compartment cover screws should be tightened to 1.48lb in.(2Nm)
Care should be taken not to over tighten the screws.