ULTRATWIN (UL)
INSTRUCTION MANUAL
176
P*814 Miscellaneous Messages
This parameter determines whether notification messages are displayed on
the auxiliary line of the display in run mode when a miscellaneous relay is
switched on or off. The message is in the form “Clock ON”.
OPTION
DESCRIPTION
0 = No (Default)
Miscellaneous messages
will not
be displayed
1= Yes
Miscellaneous messages
will
be displayed
P*815 Auxiliary Mode
The auxiliary display can be used to give additional information on
calculated values of a
point(s)
of measurement, as
determined
by
P*816
Auxiliary Source
.
The information available to be displayed will be dependent on the selected
Mode
P*100
, and the options are as follows:
OPTION
DESCRIPTION
1 = Distance
Values
related to
distance
will be
displayed
.
2 = Level (Default)
Values
related to
level
will be
displayed
.
3 = Space
Values
related to
Space
will be
displayed
.
4 = Head
Values
related to
head
will be
displayed
.
5 = Flow
Values
related to
flow
will be
displayed
.
6 = Volume
Values
related to
volume
will be
displayed
.
7 = Totaliser (R)
Values
related to
totaliser (R)
will be
displayed
.