PULSAR MEASUREMENT
177
P*816 Auxiliary Source
This parameter determines which point or points of measurement,
dependent on the selected
Mode
(
P*100
), that the auxiliary display will
relate to and the options are as follows:
OPTION
DESCRIPTION
0 = Point 1
Displays
Point 1
calculated values in chosen
Measurement Units.
1 = Point 2
Displays
Point 2
calculated values in chosen
Measurement Units.
2 = Avg. 1 & 2
Displays calculated average values of
Point 1 &
2
in chosen
Measurement Units
.
3 = Sum 1 + 2
Displays calculated sum values of
Point 1 + 2
in
chosen
Measurement Units
.
4 = Diff. 1 - 2
Displays calculated differential values of
Point 1
- 2
in chosen
Measurement Units
.
5 = Point 1
Displays
Point 1
calculated values in chosen
Measurement Units.
Important Notice
When the auxiliary display is to be used to show the value of the
average, differential
or
sum
of two points of measurement, then
both
points
must be set to the
same
units of measurement. In the case of
flow
P*100
are set for
4 (OCM Head)
or
5 (OCM Flow)
, then
P*70
6 (
Volume
Units
) &
P*707
(
Time Units
) must be the same. And in case the of
Volume
then
P*100
are set for
6 (Volume)
then
P*605 (Volume Units)
must be the same.