PARAMETER
DEFAULT
DESCRIPTION
P101 Transducer
2 = dB6
Type of transducer being used.
P102 Material
1 = Liquid
Material in the vessel, either liquid or
solid. If the solid lays flat, then it can be
programmed as liquid.
P104 Measurement
Units
4 = feet
Select units to be used for programming
measurement information.
P105 Empty Level
19.685 feet
Distance from the face of the transducer
to the material at the bottom of the
vessel.
P106 Span
10.701 feet
Distance from the empty level (0% full) to
span (100% full).
For More Options Hit Enter
PARAMETER
DEFAULT
DESCRIPTION
P213 / P214
Relay 1 ON/OFF
setpoints
Factory pre-set as a % to
appropriate level according
to the span already
entered. See tables below.
Either Alarm or Level
control. Depends on
application.
P223 / P224
Relay 2 ON/OFF
setpoints
Factory pre-set as a % to
appropriate level according
to the span already
entered. See tables below.
Either Alarm or Level
control. Depends on
application.
P233 / P234
Relay 3 ON/OFF
setpoints
Factory pre-set as a % to
appropriate level according
to the span already
entered. See tables below.
Either Alarm or Level
control. Depends on
application.
P243 / P244
Relay 4 ON/OFF
setpoints
Factory pre-set as a % to
appropriate level according
to the span already
entered. See tables below.
Either Alarm or Level
control. Depends on
application.
P253 / P254
Relay 5 ON/OFF
setpoints
Factory pre-set as a % to
appropriate level according
to the span already
entered. See tables below.
Either Alarm or Level
control. Depends on
application.
P263 / P264
Relay 6 ON/OFF
setpoints
Factory pre-set as a % to
appropriate level according
to the span already
entered. See tables below.
Either Alarm or Level
control. Depends on
application.