PT610, PT620, PT630
Instruction Manual
69
6.2.9.2 [19_] – Ethernet TCP/IP
Note:
Not available for the PT620.Only active if the option card is fitted to the PT610, PT630
.
.
The meaning of the parameters
[191]
to
[19D]
is the same as for the parameters
[151]
to
[15D]
Note:
The PT610 does not have a BARC print format.
6.2.9.3 [19_] – PROFIBUS
Note:
Not available for the PT620.Only active if the Ethercat option card is fitted to the PT610, PT630.
This sub-block includes the parameters related to the PROFIBUS interface of the indicator.
[191 FORMAT] – Data Format
INTG = Signed 32 bit integer, no decimal point implied.
FLOA = 32 bit float, decimal point implied.
[192 ADDRESS] – Rack Address
Enter a value between 001 and 125 for the rack address of the Indicator.
6.2.9.4 [19_] – PROFINET, Ethernet/IP
Note:
Not available for the PT620.Only active if the option card is fitted to the PT610, PT630.
This sub-block includes the parameters related to the PROFINET or Ethernet/IPinterface of the
indicator.
[191 FORMAT] – Data Format
INTG = Signed 32 bit integer, no decimal point implied.
FLOA = 32 bit float, decimal point implied.
[192 IP] – IP Address
Enter the IP address with the keypad. The default is “192.168.16.250”.
[194 SUB MASK] – Subnet Mask
Enter the subnet mask. The default is “255.255.255.0”.
[195 GATEWAY] – Gateway Address
Enter the IP address of the gatewaywith the keypad. The default is “192.168.16.253”.
[196 SCAL] – Device Name
Default is SCALE-1
Note:
Present for ProfiNET but not for Ethernet/IP
[19A MAC ADR] – MAC Address
Enter a MAC address for the port. The format is “AA=BB=CC=DD=EE=FF”
6.2.9.5 [19_] – CANopen
Note:
Not available for the PT620.Only active if the option card is fitted to the PT610, PT630
.
This sub-block includes the parameters related to the CANopen interface of the indicator.
[191 FORMAT] – Data Format
INTG = Signed 32 bit integer, no decimal point implied.
FLOA = 32 bit float, decimal point implied.
[192 ADDRESS] – Rack Address
Enter a value between 001 and 127 for the rack address of the indicator.
6.2.9.6 [19_] – Ethercat
Note:
Not available for the PT620.Only active if the option card is fitted to the PT610, PT630
.
This sub-block includes the parameters related to the Ethercat interface of the indicator.
[191 FORMAT] – Data Format
INTG = Signed 32 bit integer, no decimal point implied.
FLOA = 32 bit float, decimal point implied.
6.2.9.7 [19_] – CC-Link
Note:
Not available for the PT620.Only active if the option card is fitted to the PT610, PT630
.
This sub-block includes the parameters related to the CC-Link interface of the indicator.