PT610, PT620, PT630
Instruction Manual
64
Data output delay for Modbus and BSI formats; delay between continuous format data packets.
Note:
This property is very helpful for slow PLC systems.
6.2.1.9 [119 ADDRESS] – Port address
00 to 99 (00 default, 00 = transmission without address)
6.2.2 [12_] – RS-232C.2
This sub-block includes the parameters for the 2nd (RS-232C) serial interface
6.2.2.1 [121 FORMAT] – Data Format
+
NO = Port is disabled
*CONT = Continuous data output
FAST = High speed continuous data output PRNT = Printout
BSI = BSI format for PC, PLC interface
BARC = Bar code reader, ID device
MBHL = Modbus RTU High-Low format
MBLH = Modbus RTU Low-High format
Note:
BARC is not available on the PT610.
*Note:
For the RD4, RD5 and RD6 remote display interfacing, CR and LF should be enabled.
6.2.2.2 [122 BAUD] – Baud Rate
1200 = 1200
2400 = 2400
4800 = 4800
+
9600 = 9600
19K2 = 19200
38K4 = 38400
57K6 = 57600
6.2.2.3 [123 LENGTH] – Data Length
7 = 7 bits
8 = 8 bits
6.2.2.4 [124 PARITY] – Parity
+
NO = No parity
ODD = Odd parity
EVEN = Even parity
6.2.2.5 [125 CSUM] – Checksum
+
NO = no checksum
YES = checksum enabled
Enable or disable for continuous data format and BSI command mode.
6.2.2.6 [126 CR] – Carriage Return
NO = no CR
+
YES = CR enabled
Enable or disable sending of the ASCII 13 character for continuous data format.
6.2.2.7 [127 LFEED] – Line Feed
NO = no Line Feed
+
YES = Line Feed enabled
Enable or disable sending of the ASCII 10 character for continuous data format.
6.2.2.8 [128 DELAY] – Response Speed
000 to 999 miliseconds (50 default)
Data output delay for Modbus and BSI formats; delay between continuous format data packets.
Note: This property is very helpful for slow PLC systems.
6.2.2.9 [129 ADDRESS] – Port address
00 to 99 (00 default, 00 = transmission without address)
6.2.3 [13_] – RS-485
This sub-block includes the parameters for the RS-485 serial interface
6.2.3.1 [131 FORMAT] – Data Format
+
NO = Port is disabled
CONT = Continuous data output
FAST = High speed continuous data output PRNT = Printout
BSI = BSI format for PC, PLC interface
BARC = Bar code reader, ID device
MBHL = Modbus RTU High-Low format
MBLH = Modbus RTU Low-High format
Note:
BARC is not available on the PT610.
*Note:
For the RD4, RD5 and RD6 remote display interfacing, CR and LF should be enabled.