PT610, PT620, PT630
Instruction Manual
37
Note:
For the PT620 and PT630 the numerical keypad can be used to enter values.
4. Repeat from step 2 for entering following set-points.
5. The indicator returns to normal operation after displaying set-point 5 and entering its value,
6. Press the
<ESC>
key to go back in operation at any step.
Entering set-point values of items into SET memory
1. Press the
<MEM>
key for more than 2 seconds. The
[MEMORY ]
prompt appears.
2. Press the
<SETPT>
key. The last used SET memory group number appears as
[SET : 111 ]
.
3. Use this group or enter a new memory group code by pressing the
<UP>
key to increase or the
<DOWN>
key to decrease the blinking digit and press the
<CHANGE>
key to select the digit to
change.
Note:
For the PT620 and PT630 the numerical keypad can be used to enter values.
4. Press the
<ENTER>
key to enter into the item.
5. The first set-point value is seen on the display as
[SET 111 - SP1 ] [ 10.00 kg ]
. Enter the new
value by pressing the
<UP>
key to increase or the
<DOWN>
key to decrease the blinking digit and
press the
<CHANGE>
key to select the digit to change. Press the
<ENTER>
key to confirm.
Note:
For the PT620 and PT630 the numerical keypad can be used to enter values.
6. The next limit value appears as
[SET 111 - SP2 ] [ 20.00 kg ]
. Enter new value as above and
press the
<ENTER>
key.
7. Repeat steps 4 and 5 for entering values into the other three set-point values of the group.
8. After entering the value of 5th set point value press the
<ENTER>
key to go to the next memory
group.
9. Or press the
<ESC>
key to exit.
Select set-point limits for an item from SET memory
1. Press the
<SETPT>
key. The last used set-point value appears on the display as
[SP1 1250 kg ]
.
2. Press the
<MEM>
key. The last used SET memory group code appears on the display
[SET : 111 ]
.
3. Enter the memory code of the item by pressing the
<UP>
key to increase or the
<DOWN>
key to
decrease the blinking digit and press the
<CHANGE>
key to select the digit to change.
Note:
For the PT620 and PT630 the numerical keypad can be used to enter values.
4. Press the
<ENTER>
key to confirm.
5. The selected SET memory data is loaded after displaying values.
6. Or press the
<ESC>
key to exit without loading the values.
This weighing terminal may be equipped with 5 programmable set-points to use them at weighing
process. If the specified set point values are exceeded or dropped below, digital outputs are set, e.g. for
controlling flaps, valves, lamps etc.
Digital Inputs:
Digital inputs which are independently programmable for zeroing, taring, clear, print, key lock and as a
fieldbus input port in industrial weighing applications.
Figure 12.2 - Connection diagram of the inputs. U is an external power source.
Digital Outputs:
Digital outputs can be programmable as a free set-point or as a dialogue port to control them with a
host command.