Model specific specifications
PT620
Digital filter
5 step programmable adaptive digital filter.
Dynamic/Animal weighing with multiple settings.
Additional standard applications
Check-weighing, classifying, filling, counting and high resolution scales
Additional weighing functions
Piece Counting, Weight Totalling, Piece Totalling, Pre-Tare entry.
Additional data storage
Pre-Tare value storage (500 values), ID data (ID1, 500 records for stored
items), ID data (ID1, 500 records for stored items), ID Data (ID2, second set
500 records), Average Piece Weight storage for counting (500 values)
Communications
Command, continuous, Printer, BSI, BSI-PRO communications.
Display
3 backlight colours, selectable or programmable, smart bar status.
PT630
Digital filter
5 step programmable adaptive digital filter.
Dynamic/Animal weighing with multiple options.
Additional standard applications
Check-weighing, classifying, filling, counting and high resolution scales
Ethernet onboard
10 / 100 Mbit/s, Full duplex. Manual IP assigned with EtherX PC Software or
by front panel in programming mode. Server or Client modes. Switched
Ethernet transmission with shielded twisted pair cables and RJ-45.
Galvanically isolated bus electronics. Up to 4 ms response delay after
read/write commands.
Communications
Command, continuous, Printer, BSI, BSI-PRO communications.
Additional weighing functions
Piece Counting, Weight Totalling, Piece Totalling, Pre-Tare entry.
Additional data storage
Pre-Tare value storage (500 values), ID data (ID1, 500 records for stored
items), ID data (ID1, 500 records for stored items), ID Data (ID2, second set
500 records), Average Piece Weight storage for counting (500 values)
Display
3 backlight colours, selectable or programmable, smart bar status.
Option specifications – Refer 2.4MODELS and FEATURES table for applicability.
Alibi Memory
Medium
SD card.
Storage
Up to 999999 records.
Modbus SD (RTU /TCP) for on-board ports
Medium
SD card with software
Protocol
RTU for RS232C and RS485, TCP for Ethernet
Response Speed
< 4mS response delay from read/write commands.
Digital Input/Output option card
Digital Inputs
Opto-isolated 4 digital input, 12 to 28 VDC, 10mA
Digital Outputs
5 relay outputs, maximum 250 VAC or 30 VDC, 0.2A
Analogue option card
Analogue output
4–20, 0–20mA, 0–5VDC, 0–10VDC. Max 60000 steps, load 500Ω - 10kΩ
Digital Inputs
Opto-isolated 4 digital input, 12 to 28 VDC, 10mA
Digital Outputs
5 relay outputs, maximum 250 VAC or 30 VDC, 0.2A
Response Speed
< 4mS response delay from read/write commands.
PROFIBUS option card
Protocol and Data Rate
PROFIBUS DP V1. 9.6 kbit/s to 12 Mbit/s automatic baud rate detection,
PLC setup
Generic GSD-file provided.
Topology
Media dependent, RS-485 segmented line without stubs.
Installation
Shielded twisted pair cable, line length depending on physical media and
transmission speed.
Maximum stations
Up to 32 stations per segment, up to 126 stations per network.
Isolation
Galvanically isolated bus electronics.
Response Speed
< 4mS response delay from read/write commands.
Digital Inputs
Opto-isolated 4 digital input, 12 to 28 VDC, 10mA
Digital Outputs
5 relay outputs, maximum 250 VAC or 30 VDC, 0.2A
PROFINET option card
Data Rate
100 Mbit/s, full duplex
PLC setup
Generic GSDML-file provided
TCP/IP settings
DHCP or manual IP assignment EtherX PC Software or by front panel in
programming mode. Device identity customization.
Topology
Line, Bus, Star or Tree topology depending on physical media.