PT610, PT620, PT630
Instruction Manual
43
Product Limit values for Classifying
The entry type can be selected as a weight value, deviation from target or percentage of the target in
parameter
[312]
(6.4.1.2). This selection defines the SET value’s entry as shown below;
Entry type
Target
Lowest
Limit -T2
Low limit
-T1
High limit
+T1
Highest
Limit +T2
Unloaded
scale limit
Value
TARGET
- - LOW
-LOW
+HIGH
++HIGH
EMPTY
Deviation
TARGET
- - TOL
-TOL
+TOL
++TOL
EMPTY
Percent %
TARGET
- - TOL
-TOL
+TOL
++TOL
EMPTY
The target (nominal value), low, high and empty range entries should be entered with a weight value in
the units defined for the scale; Tolerance entries should be entered as deviation from nominal weight in
scale units or in percentage.
The descriptions below are considered the value entry type. Follow in a similar way for entry types
deviation or percentage.
Enter the nominal value and limits by keys
1. Press the
<SET>
key for more than 2 seconds.
2. The current target value is seen on the display as
[ TARGET 1250 kg ]
. Enter the new value with
the numerical keys. Press the
<ENTER>
key to save it or press the
<ESC>
key to return to operation
without saving.
3. The lowest tolerance prompt
[ --LOW : 1234.6]
will show you the current lowest value. Enter the
new value with numerical keys. Press the
<ENTER>
key to save it or press the
<ESC>
key to return
to operation without saving.
4. The
[ -LOW: 1245.6]
prompt will show you the current low tolerance. Enter the new value with the
numerical keys. Press the
<ENTER>
key to save it or press the
<ESC>
key to return to operation
without saving.
5. The
[ +HIGH: 1255.6]
prompt will show you the current high tolerance. Enter the new value with the
numerical keys. Press the
<ENTER>
key to save it or press the
<ESC>
key to return to operation
without saving.
6. The
[ ++HIGH: 1260.0]
prompt will show you the current highest tolerance. Enter the new value with
the numerical keys.
7. The
[ EMPTY: 100.0]
prompt will show you the current empty range of the platform. Enter the new
value with the numerical keys.
8. Press the
<ENTER>
key to return to operation after saving the entry or press the
<ESC>
key to
return to operation without saving.
Entry product limits into SET memory
1. Press the
<MEM>
key for more than 2 seconds. The
[ MEMORY]
prompt appears.
2. Press the
<SET>
key. The last used SET memory code appears, I.e.
[ SET :001]
.
3. Enter the new memory code if different by using the numerical keys and press the
<ENTER>
key.
4. The target value is seen on the display as
[ SET 001: TARGET ], [ 1250 kg ]
. Enter the new
target with the numerical keys and press the the
<ENTER>
key.
5. The lowest tolerance prompt
[ --LOW : 1234.6]
appears. Enter the new value with numerical keys
and press the
<ENTER>
key.
6. The low tolerance prompt
[ -LOW : 1245.6]
appears. Enter the new value with the numerical keys
and press the
<ENTER>
key.
7. The high tolerance prompt
[ +HIGH : 1255.6]
appears. Enter the new value with the numerical keys
and press the
<ENTER>
key.
8. The highest tolerance prompt
[ ++HIGH : 1260.0]
appears. Enter the new value with the numerical
keys and press the
<ENTER>
key.
9. The
[ EMPTY: 100.0 ]
prompt appears on the display. Enter the new value with the numerical keys.
10. Press the
<ENTER>
key to go to the following memory after saving or press the
<ESC>
key to return
to operation without saving.
Select product limits from SET memory
1. Press the
<SET>
key for more than 2 seconds. The current target value appears on the display as
[ TARGET: 1250 kg ]
.
2. Press the
<MEM>
key to enter SET memory. The last used SETt memory code appears on the
display as
[ SET:001]
.
3. Enter the memory code of the product if different using the numerical keys and press the
<ENTER>