Connecting equipment to the Plus Touch
17
To connect curtain machines
Connect curtain machines to the Plus Touch as shown.
Connecting cooling, heating, and duty cycle equipment to relays
Heating or cooling equipment includes electric heaters, furnaces, single-speed fans, and any other
equipment that is either on or off.
The ratings of the equipment must not exceed the ratings of the Plus Touch relays.
Plus Touch relay ratings
: 10 A at 120/230 VAC, general-purpose (resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
360 W tungsten at 120 VAC
Gas furnaces using hot-surface ignition or glow plug can draw more current than
indicated on their nameplate and require power contactors. For more information,
read your furnace dealer.