Appendix E: Settings worksheets
85
Curtain worksheet
Curtains control the temperature by adjusting the air flow into the facility. Each curtain has six
settings.
Set point
– the temperature at which the curtain holds its position.
Idle band
– the buffer around the set point within which the curtains hold their position.
Open run duration
– the duration the curtains open during the open cycle
Open idle duration
– the duration the curtains hold their position during the open cycle
Close run duration
– the duration the curtains close during the close cycle
Close idle duration
– the duration the curtains hold their position during the close cycle
Programming curtain control relays
Curtain
Set point
Idle band
Open run
duration
Open idle
duration
Close run
duration
Close idle
duration
:
:
:
:
:
:
:
:
:
:
:
:
Temperature in °F/ °C, range: -25 to 51.7°C (-13 to 125°F)
Temperature in °F/ °C, range: 0.6 to 5.5°C (1.0 to 10.0°F)
Duration in mm:ss, range: 0 to 59 minutes in 1 second increments
Heating, cooling, and duty cycle relay worksheet
There are three types of heating and cooling relay configurations: cooling, cooling duty cycle,
heating, and heating duty cycle. For more information, read:
Configuring relays for heating, cooling, or duty cycle