Configuring equipment
35
To calibrate inlet actuators
1.
At the Status screen, press the widget for the actuator you want to calibrate.
2.
Press
Calibrate
.
3.
Press
Yes
to start calibration or
No
to cancel.
If you started calibration, the actuator should open all the way and then close all the way. If
calibration is successful, the actuator will move into position according to its settings.
Configuring relays for heating, cooling, or duty cycle
Relays configured for cooling can control equipment such as fans or misters that you want on when
temperatures are above the set point and off when they are below it.
Relays configured for heating can control equipment such as heaters or furnaces that you want on
when temperatures are below the set point and off when they are above it.
Relays configured for duty cycle will switch on and then off for specified durations when
temperatures are above (cooling) or below (heating) their set points. For more information about
duty cycles, read
on page 81 when configuring relays.