Appendixes
86
Relay
Type
Set point
Duty cycle
Type
ON duration
OFF duration
Relay 5
Heat Ventilation
Temperature
01:30
03:00
Relay 1
Heat Ventilation
:
:
:
Relay 2
Heat Ventilation
:
:
:
Relay 3
Heat Ventilation
:
:
:
Relay 4
Heat Ventilation
:
:
:
Relay 5
Heat Ventilation
:
:
:
Relay 6
Heat Ventilation
:
:
:
Temperature in °F/ °C, range: -25 to 51.7°C (-13 to 125°F)
Duration in mm:ss, range: 0 to 59 minutes in 1 second increments
Temperature based, time based, or persistent
Alarm settings worksheet
The alarm settings for the Plus Touch determine which alarm conditions are enabled, which are
disabled, and their settings. All these work together to determine how and when the alarm relay
activates (in other words, signals an alarm condition).
The alarm relay activates if an alarm condition (one that is enabled) is present for longer than the
minimum duration of one minute. The one minute minimum duration prevents alarms from
occurring when the temperature rises or drops for just a few seconds. For more information, read
Programming alarms
Alarm
Status
Setting
Description
High temperature
Enabled
Not enabled
The highest temperature to which you can
safely allow your facility to rise
–
cannot be
lower than low temperature alarm.
Low temperature
Enabled
Not enabled
The lowest temperature to which you can
safely allow your facility to fall
–
cannot be
higher than high temperature alarm.
Probe damage
Enabled
Not enabled
-----
The temperature sensor is damaged or
disconnected.
Inlet 1 jam
Enabled
Not enabled
-----
The actuator or curtain cannot move.
Inlet 2 jam
Enabled
Not enabled
-----
The actuator or curtain cannot move.
Temperature in °F/ °C, range: -25 to 51.7°C (-13 to 125°F)