Programming equipment settings
55
on page 85 when setting up curtains.
To program curtain machines
1.
Press the
Menu
and then
Settings
.
2.
Press
Staged Ventilation
.
3.
Press
Curtains
Idle band
(+/
–
2°F)
When the temperature is within the idle band,
the curtain remains in its current position.
Set point
(80°F)
Open run duration
(00:30 mm:ss)
If the temperature rises above the idle band,
the curtain opens for this duration.
Open idle duration
(02:00 mm:ss)
After the curtain opens for the open run duration,
it holds its position for the open idle duration.
Time (duration)
Close run duration
(01:00 mm:ss)
If the temperature falls below the idle band,
the curtain closes for the close on duration.
Close idle duration
(01:00 mm:ss)
After the curtain closes for the open run duration,
it holds its position for the close off duration.