Chapter 2: Installing the Plus Touch
12
Bottom layout
Voltage selection switch
–
set this switch to the correct voltage before installing the Plus Touch.
Variable stage fuses (F1, F2)
–
15 A, 250 VAC ABC-type ceramic; F1 VAR 1, F2 for VAR 2.
Variable stage terminals (VAR1, VAR2)
–
connect variable speed fans to these terminals.
Relay terminals (RLY1 to RLY6)
–
connect single stage (on/off) equipment to these terminals. You can configure
these relays as heat, cool, duty cycle, inlet, or to follow another variable or relay.
Incoming power terminal
–
connect the incoming power (120/230 VAC, 50/60 Hz) to this terminal.
Alarm relay terminal
–
connect an external alarm system or alarm siren to this terminal.
Actuator feedback terminals (ACT1 and ACT2)
–
connect the feedback from the actuators to these is terminals.
Phason 3K temperature sensor terminals (TEMP1 to TEMP4)
–
connect the sensors to these terminals.
Display cable
–
make sure the ribbon cable from the display is properly connected to the socket.
1
2
3
4
5
6
7
8
9
4
3
6
7
8
9
1
2
5