Chapter 4: Programming the Plus Touch
42
The minimum ventilation curve affects only the first variable stage that is configured as cooling for
the zone. The following examples show which variable stage would be affected by the minimum
ventilation curve in different situations.
Example 1
Example 2
Example 3
VAC 1 - Cool
VAC 2 - Cool
Controlled by curve
Not controlled
VAC 1 - Heat
VAC 2 - Cool
Not controlled
Controlled by curve
VAC 1 - Unused
VAC 2 - Unused
VDC 1 - Unused
VDC 2 - Cool
VDC 3 - Heat
VDC 4 - Unused
Not controlled
Not controlled
Not controlled
Controlled by curve
Not controlled
Not controlled
Curve length and current day
Curve length is the number of days in the curve. Curves can have up to 365 days. Current day
defines which day's settings Plus Touch is using.
To program minimum ventilation curves
1.
Press the
Menu
and then
Settings
.
2.
Press
Staged Ventilation
.
3.
Press
Ventilation Curve
.
4.
Below
Zone
, press the
Left
or
Right
arrow to choose the zone.
5.
Below
Step Start Day
, press the
Up
or
Down
arrows to set the start day for each step.
6.
Below
Restart Day
, press the
Left
or
Right
arrow to choose the zone.
7.
Below
Minimum Ventilation Rate
, press the
Up
or
Down
arrows to set the idle speed for the start
day of each step.
8.
When finished, press
Save
.
Before you can set the current day, you must configure the zone to use the
minimum ventilation curve. For more information, read
Configuring the zone
control mode