Chapter 2: Installing the Plus Touch
14
Mounting the Plus Touch
1.
Select a location for the Plus Touch. Make sure you have
enough cable and wire to reach all the equipment (fans,
heaters, misters, curtains, etc.) that you want to control.
2.
Remove the screws from the front cover and then gently lift
it off.
3.
Mount the enclosure to a wall using the four screws provided
with the control. Insert the screws into the large holes in each
corner of the box and tighten.
Connecting equipment to the Plus Touch
Follow these instructions when installing the Plus Touch and connecting equipment to it.
Use the electrical knockouts for bringing wires or cables into or out of the Plus
Touch enclosure. Do not make additional holes in the enclosure; this can damage
the watertight seal or control components and void the warranty.
Plus Touch test modes are useful for testing your equipment after installing and
configuring it. For more information, read
page 63.
Refer to
Appendix C: Installation worksheet
on page 79 when installing equipment.
Connecting actuators
You can connect up to two actuators to a Plus Touch. Actuators are used for equipment that is not
OFF or ON, but instead varies by a percentage. For example, inlets can be open various distances
from 0 percent to 100 percent.
Linear actuators are usually connected directly to inlets, or using cables and pulleys. Inlets are
generally located in the ceiling or walls. Inlet systems are usually spring loaded to aid in closing the
inlet, or counter weighted to aid in opening the inlets.
Each actuator you connect requires two relays: one for opening, and one for closing. Actuators must
be connected in the following combinations.
Actuator 1:
Relay 1 – open
Actuator 2:
Relay 3 – open
Relay 2 – close
Relay 4 – close