Chapter 4: Programming the Plus Touch
40
For example, in the table on the right, the duration of
step 2 is 10 days. The difference between the starting
set point (86.5°F) and the starting set point for the
next step (85°F) is 1.5°F.
Plus Touch divides the temperature difference by the
duration, 1.5 ÷ 10 = 0.15, and then automatically
adjusts the set point by 0.15°F each day for 10 days.
Use the
Growth curve worksheet
on page 82 when programming growth curves.
If you have a growth curve controlling the zone, you cannot adjust the master
set point.
The growth curve resets at the
beginning
of the restart day.
Step
Temperature (°F)
Duration (days)
1
2
3
4
5
6
7
88.0
86.5
85.0
83.5
81.0
78.0
74.0
5
10
10
10
5
5
10
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Day 1
Day 5
Day 15
Day 25
Day 35
Day 40
T
Day 45
Day 55
90°F
85°F
80°F
75°F
70°F
Temp
er
at
ur
e