Chapter 2: Installing the Plus Touch
18
To connect equipment to relays
Connect equipment as shown below.
Connecting variable heating or cooling equipment
Variable cooling equipment includes equipment such as variable-speed fans. Variable heating
equipment includes equipment such as heat mats and heat lamps.
Only permanent split capacitor motors appropriate for variable speed control, or
shaded pole motors, can be used on the variable stages.
If you are using three-phase power, connect the Plus Touch and the variable
cooling equipment to the same phase. For more information, read
Using three-
phase power
The ratings of the equipment must not exceed the ratings of the Plus Touch’
variable stages.
Variable stage ratings
10 A at 120/230 VAC, general-purpose (resistive)
7 FLA at 120/230 VAC, PSC motor
1/2 HP at 120 VAC, 1 HP at 230 VAC, PSC motor
Variable stage fuses
15 A, 250 VAC ABC-type ceramic
Gas-fired furnace or brooder
All other single-speed heating or cooling elements