Appendix B: Factory defaults
The Plus Touch leaves the factory with default configuration and settings. Resetting the Plus Touch
erases all the configuration and settings you programmed and restores them to what they were when
the control left the factory. For more information, read
Restoring the factory defaults
Configuration
Variable cooling
Variable and relay stages
Sensors
Zone function
Temperature units
Screen lock
Hysteresis
Relay stagger
Alarm silencing
Not configured
Not configured
Staged, curves not enabled
°F
Off
1.0
5 sec
15 minutes
Differential
Set point
Idle range
Idle speed
86.0°F
80.0°F
75.0°F
20%
Variable heating
Differential
Set point
Heat cutoff
Minimum heat
70.0°F
75.0°F
77.0°F
20%
Master set point / growth curve
Ventilation curve
Master set point
Current day
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Restart day
75.0°F
0 / off
day 1 , 85.0°F
day 4, 80.0°F
day 14, 75.0°F
day 24, 70.0°F
day 34, 65.0°F
day 44, 60.0°F
day 64, 60.0°F
Current day
Step 1 start, day 4
Step 2 start, day 14
Step 3 start, day 24
Step 4 start, day 34
Step 5 start, day 44
Step 6 start, day 54
Step 7 start, day 74
Restart day
0 / off
day 1, 20%
day 4, 25%
day 14, 30%
day 24, 35%
day 34, 40%
day 44, 45%
day 64, 50%
1
Alarm settings
Min.
Stage 1
Stage 2
Stage 3
Stage 4
Stage 5
SP 72°F, Pos 0%
SP 75°F, Diff 79.0, Pos 20%
SP 79°F, Diff 81.0, Pos 40%
SP 81°F, Diff 83.0, Pos 60%
SP 83°F, Diff 85.0, Pos 80%
SP 85°F, Diff 87.0, Pos 100%
High temperature
Low temperature
Probe damage
Actuator jam
Not enabled / 95.0°F
Not enabled / 60.0°F
Not enabled
Not enabled