Chapter 3: Configuring your Plus Touch
28
To configure hysteresis
1.
Press the
Menu
and then
Configuration
.
2.
Press
Hysteresis
.
3.
Press the
Up
or
Down
arrows to adjust the hysteresis value.
4.
Press
Save
.
Configuring relay stagger
Relay stagger prevents several relays from switching on at the same time by offsetting each relay
when the control starts. Inlet relays are not affected by relay stagger.
Let’s say you have relays 1 and 2 configured for inlets; relays 3, 4, and 5 configured for cooling; and
relay 6 configured for heating. The temperature is above the set point. This is what will happen
when the control starts.
Relays 1/2: not affected by relay stagger, switch on immediately
Relay 3:
switch on immediately
Relay 4:
switch on 5 seconds after relay 3
Relay 5:
switch on 5 seconds after relay 4
Relay 6:
remain off
Default:
5 seconds
Range:
0 to 59 seconds
To configure relay stagger
1.
Press the
Menu
and then
Configuration
.
2.
Press
Relay Stagger
.
3.
Press the
Up
or
Down
arrows to change stagger duration.
4.
Press
Save
.
Configuring alarm silencing
Alarm silencing is the amount of time an alarm is temporarily disabled (silenced) after it has been
acknowledged. Alarm silencing prevents the alarm relay from triggering immediately if it has been
acknowledged when the alarm condition is still present. If the alarm condition is still present after
the silencing duration, the alarm triggers again.
Default:
15 minutes
Range:
1 to 240 minutes (4 hours)