176
Setup: Item Settings
691
UMID GEN
0000
0001
INT
EXT
Specifies the generation method of UMID information that is recorded when setup menu
No. 690 (UMID REC) is set to ON.
0: Newly created UMID information is always recorded.
1: Records UMID data superimposed on the input signal.
Newly created UMID information is recorded when not superimposed on an input
signal.
692
UMID POS
0000
0001
:
0006
:
0008
BLANK
12L
:
17L
:
19L
Specifies the line that superimposes UMID data.
NOTE:
• You cannot select the same line as in menu No. 501 VITC POS-1 and No. 502
VITCPOS-2.
• Holding down the STILL button and pressing the RESET button will not restore the
factory defaults.
• UMID data is output before recorded VANC data. To output VANC data, set UMID
POS to a line other than that which superimposed the data or select “BLANK.”
• During playback of DVCPRO HD native clip, UMID becomes NO-INFO.
693
GAMMA SEL
0000
0001
0002
0003
OFF
GAMMA1
GAMMA2
GAMMA3
Selects gamma correction.
0: No gamma correction
1: Corrects video shot by Varicam or in the
FILM REC mode on an AJ-HPX3000 to film-
quality video. (Equivalent to TELECINE 5 on
the AJ-GBX27HD Gamma Corrector)
2: Corrects video shot by Varicam or in the
FILM REC mode on an AJ-HPX3000 to film-
quality video. (Equivalent to TELECINE 6 on
the AJ-GBX27HD Gamma Corrector)
3: Converts video shot by Varicam or in the
FILM REC mode on an AJ-HPX3000 by
applying a Cineon curve to produce video appropriate for film recording.
NOTE:
• This setting is available during playback.
• Selecting something other than OFF superimposes the text GAMMA on the screen.
• Turning the power off cancels the GAMMA setting.
• This item has no effect during 1394 output.
Item
Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.
1023
768
512
256
256
512
768
1023
VI
DEO
L
E
V
E
L
LUMINANCE
TELECINE5
TELECINE6
Cineon