166
Setup: Item Settings
This menu allows you to set method for engaging search dial operations, maximum shuttle speed operation, maximum speed
of FF and REW operation, NEXT and PREV seek operations, display of warning messages when REF.VIDEO is not connected,
PLAY delay time, battery type, display of warnings when power is too low, voltage when the power supply is turned off.
•
XX
indicates factory default settings.
OPERATION
Item
Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.
100
SEARCH ENA
0000
0001
DIAL
KEY
Specifies method for transferring to the search mode (search dial operation).
0: Press the STILL button or turn the search dial to engage search dial operation.
1: Press the STILL button to engage search dial operation.
101
SHTL MAX
0000
0001
0002
0003
0004
×8
×
16
×32
×60
×100
Sets the maximum shuttle speed operation.
0: 8× normal speed
1: 16× normal speed
2: 32× normal speed
3: 60× normal speed
4: 100× normal speed
102
FF.REW MAX
0000
0001
0002
0003
×
32
×60
×100
SEEK
Sets the maximum speed of FF and REW operation.
0: 32× normal speed
1: 60× normal speed
2: 100× normal speed
3: Seek operation to start of clip
NOTE:
• When SEEK is selected, FF and REW operations for FF and REW commands
transferred via 9P and 1394 are performed at 100× normal speed. Note that seek
operations initiated by the FF and REW commands via 9P behave differently when
ORIG is set in setup menu No. 202 (ID SEL). The cursor moves to left or right in
thumbnail screens.
• The seek operation is available in playback mode.
103
SEEK SEL
0000
0001
CLIP
CLIP&T
Specifies where a NEXT (SHIFT+FF) and PREV (SHIFT+REW) seek operation moves to.
0: The start of the clip
1: The start of the clip or video text memo
NOTE:
This setting is not available during FF and REW operation.
104
REF ALARM
0000
0001
OFF
ON
Selects whether or not a warning should appear when REF.VIDEO is not connected.
0: Displays no warning
1: Flashes the STOP lamp to warn
108
PLAY DELAY
0000
|
0015
0
|
15
Sets PLAY delay time in frame increments.
122
STOP EE SEL
0000
0001
EE
PB
Specifies whether to invoke the EE mode or playback mode when STOP is pressed.
0: EE mode
1: Playback mode
NOTE:
• During IEEE1394 signal input, the EE mode is invoked regardless of this menu
setting.
• Selecting PB displays a freeze picture of the last video for VIDEO OUT and SDI OUT
output during thumbnail display.
147
WFM DISP
0000
0001
0002
OFF
WAVE
VECTOR
Selects wave form monitor (WFM) display mode.
0: Not displayed
1: Waveform display
2: Vector display
NOTE:
The waveform monitor is not displayed when there is no input.