170
Setup: Item Settings
502
VITC POS-2
When set to 59.94 Hz,
29.97 Hz
Specifies the position where the VITC signal will be inserted.
NOTE:
• You cannot select the same line as in setup menu No. 501 (VITC POS-1).
• This setting is available only during analog composite output and SD SDI output.
0000
|
0008
|
0010
10L
|
18L
|
20L
When set to 50 Hz,
25 Hz
0000
|
0006
|
0015
7L
|
13L
|
22L
504
RUN MODE
0000
0001
REC
FREE
Specifies an operating mode that advances the internal time code generator.
0: The internal time code generator is advanced only during recording.
1: When the power is on, the internal time code generator is advanced regardless of
operating mode.
NOTE:
When setup menu No. 040 (VFR REC) is set to ON, the time code advances only during
recording even when FREE is selected.
505
TCG REGEN
0000
0001
0002
TC&UB
TC
UB
Specifies the signal to regenerate when the time code generator (TCG) is in the REGEN
mode.
0: Regenerates both the time code and the user bit
1: Regenerates only the time code
2: Regenerates only the user bit
507
EXT TC SEL
0000
0001
0002
EXT_L
SLTC
SVITC
Specifies the time code used when an external time code is used.
0: LTC of the TIME CODE IN connector
1: LTC data attached to serial signal input to HD SDI IN
2: VITC data attached to serial signal input to HD SDI IN
NOTE:
When SLTC and SVITC are set, the VITC in the input video signal is used when an
analog composite or SD SDI input signal is selected. When 1394 is selected as the
input signal, the IEEE 1394 digital input signal time code is used regardless of this
setting.
508
BINARY GP
0000
0001
0002
0003
0004
0005
0006
0007
000
001
010
011
100
101
110
111
Specifies user bit usage in time code generated by the TCG.
0: NOT SPECIFIED (character set not specified)
1: ISO CHARACTER (8-bit character set complying with ISO646 and ISO2022)
2: UNASSIGNED 1 (undefined)
3: UNASSIGNED 2 (undefined)
4: UNASSIGNED 3 (undefined)
5: PAGE/LINE
6: UNASSIGNED 4 (undefined)
7: UNASSIGNED 5 (undefined)
509
PHASE CORR
0000
0001
OFF
ON
Specifies whether or not LTC output from the TIME CODE OUT connector should be
phase controlled.
0: No phase control
1: Phase controlled
510
TCG CF FLAG
0000
0001
OFF
ON
Sets the TCG CF flag.
0: OFF
1: ON
Item
Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.
59.94Hz
50Hz
29.97Hz
25Hz
only
59.94Hz
50Hz
23.98Hz
24Hz
29.97Hz
25Hz
only
59.94Hz
50Hz
23.98Hz
24Hz
29.97Hz
25Hz
only
59.94Hz
50Hz
29.97Hz
25Hz
60-25Hz