All BASIC commands
Section 4-2
233
4-2-201 REP_OPTION
/i
/i
/i
Type
Axis parameter
Syntax
REP_OPTION
Description
The
REP_OPTION
parameter controls the application of the
REP_DIST
axis parameter and the repeat option of the
CAMBOX
and
MOVELINK
Axis commands. The default value is 0. See the
table below.
Bit
Description
0
The repeated distance range is controlled by bit 0 of the
REP_OPTION
param-
eter.
•
If
REP_OPTION
bit 0 is off, the range of the demanded and measured posi-
tions will be between
-REP_DIST
and
REP_DIST
.
•
If
REP_OPTION
bit 0 is on, the range of the demanded and measured posi-
tions will be between 0 and
REP_DIST
.
1
The automatic repeat option of the
CAMBOX
and
MOVELINK
commands are
controlled by bit 1 of the
REP_OPTION
parameter. The bit is set on to request
the system software to end the automatic repeat option. When the system soft-
ware has set the option off it automatically clears bit 1 of
REP_OPTION
.
Arguments
N/A
Example
No example.
See also
AXIS
,
CAMBOX
,
MOVELINK
,
REP_DIST
.