![background image](http://html1.mh-extra.com/html/omron/omnuc-w-r88a-ncw152-drt/omnuc-w-r88a-ncw152-drt_manual_743096253.webp)
9 Troubleshooting
9-42
9
CPF00
CPF00: Parameter Unit Transmission Error 1
This alarm is not stored in the alarm record function memory.
Display and Outputs
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
Not specified
Cause
Remedy
A
Cable defective or poor contact between
Parameter Unit and Servo Driver
• Check connector connections.
• Replace cable.
B
Malfunction due to external noise
Separate Parameter Unit and cable from
noise source.
C
Parameter Unit is defective.
Replace Parameter Unit.
D
The Servo Driver is defective.
Replace the Servo Driver.