9 Troubleshooting
9-28
9
A.C1
A.C1: Runaway Detected
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state). ON: Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
ON
OFF
ON
OFF
Cause
Remedy
A
Servomotor wiring incorrect or discon-
nected.
Check wiring and connectors at Servomo-
tor.
B
Encoder wiring incorrect or disconnected.
Check wiring and connectors at encoder.
C
Encoder is defective.
Replace the Servomotor.
D
Circuit board (1PWB) is defective.
Replace the Servo Driver.
D
A,
B,
C,
D
A,
B,
C
A,
B,
C,
D
At
power
ON
Parameter
Pn50A.1=7
Occurred
1
to
3
seconds
after
power
ON
Parameter
Pn50A.1=
Other
than
ì7î
When
servo
ON
(RUN)
signal
turned
ON
On
speed
reference
input