![background image](http://html1.mh-extra.com/html/omron/omnuc-w-r88a-ncw152-drt/omnuc-w-r88a-ncw152-drt_manual_743096140.webp)
6.6 Details on Move Commands for Remote I/O Communications
6-43
6
Operation
Command Method
1. Set the Servo ON Command (byte 0, bit 1) to 1.
2. Set the movement direction (byte 3, bit 1).
3. Set the override value. The Pn830 setting determines whether the override will be set as
a ratio (%) or as a speed (
×
1000 steps/min).
4. Set the JOG Command (byte 2, bit 3) to 1.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
0
0
0
1
0
0
1
0
1
Response type
0 Hex
2
0
0
0
0
1
0
0
0
3
0
0
0
0
0
0
DIR
0
4
Override value (0 to 200 [%]) or
JOG speed (0 to 240,000 [
×
1000 steps/min] )
5
6
7
Pn831
Time
Speed
JOG
DIR
1
0
1
0