4 Connectors
4.3.1 Connection Example of I/O Signal Connector (CN1)
4-6
4
4.3 Servo Driver I/O Signals
This section describes I/O signals for the Servo Driver with the DeviceNet Unit.
4.3.1 Connection Example of I/O Signal Connector (CN1)
The following diagram shows a typical example of I/O signal connections.
* 1. When using an absolute encoder, connect a backup battery only when
there is no battery connected to the CN8.
* 2. Make signal allocations using parameters. Refer to
8.1.3 Standard Set-
tings for I/O Signals
.
Note 1.
Input signal settings are changed by the DeviceNet Unit and cannot be changed by the user.
2.
The functions of the output signals on pins 25 to 30 and the polarity (effective high/low) of the
input signals on pins 41 to 45 can be changed using the parameter settings. (The diagram above
shows the standard settings.)
Fig. 4.1 I/O Signal Connections for CN1 Connectors
Not used
INP1
Positioning completed 1
Brake interlock
Servo ready
Alarm
INP1COM
25
26
BKIR
BKIRCOM
READYCOM
27
28
READY
29
30
ALMCOM
ALM
31
32
ALO2
ALO1
ALO3
37
38
39
Ground common
GND
1
46
45
ZERO
44
EXTP
43
NOT
42
POT
41
ORG
3.3k
40
47
+24VIN
Origin
Interrupt
Reverse
rotation drive
prohibited
Forward
rotation drive
prohibited
Origin
proximity
24VDC
Frame ground
FG
Shell
Maximum operating voltage:
30 VDC
Maximum output current:
20 mA DC
3.3k
3.3k
3.3k
3.3k
3.3k
3.3k
3.3k
3.3k
3.3k
3.3k
3.3k
3.3k
3.3k
GND
1
Backup
battery
21
22
BAT
BATGND
2.8 to 4.5V
Not used
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
*
1
*
2
Maximum operating voltage:
30 VDC
Maximum output current:
20 mA DC
Alarm code
Содержание OMNUC W R88A-NCW152-DRT
Страница 1: ...Cat No I538 E3 1 DeviceNet Option Unit OMNUC W Series Model R88A NCW152 DRT...
Страница 53: ...4 Connectors 4 5 3 DeviceNet Network Configuration Restrictions 4 22 4...
Страница 97: ...5 Parameter Settings 5 3 8 Notch Signal Output Positioning 5 44 5...
Страница 211: ...8 Servo Driver Settings 8 5 3 Absolute Encoder Multi turn Limit Setting 8 24 8...
Страница 257: ...9 Troubleshooting 9 46 9...