10.2 DeviceNet Attributes
10-21
10
60
Get/Set
Feed-forward Com-
mand Filter
UINT
Sets the feed-forward command filter.
Unit: 0.01 ms
0 to 6400
0
61
Get/Set
Speed Control Set-
ting
UINT
Sets the speed control.
−
0004
62
Get/Set
P Control Switching
(Torque
Commands)
UINT
Sets the P control switching
(torque commands).
Unit: %
0 to 800
200
63
Get/Set
P Control Switching
(Speed Commands)
UINT
Sets the P control switching
(speed commands).
Unit: r/min
0 to 10000
0
64
Get/Set
P Control Switching
(Acceleration Com-
mands)
UINT
Sets the P control switching (accelera-
tion ).
Unit: 10 r/min/s
0 to 3000
0
65
Get/Set
P Control Switching
(Deviation Pulse)
UINT
Sets the P control switching (deviation
pulse).
Unit: pulse
0 to 10000
10
66
Get/Set
Online Autotuning
Setting
UINT
Sets the online autotuning.
−
0012
67
Get/Set
Speed Feedback
Compensating Gain
UINT
Sets the speed feedback compensation.
Unit: %
1 to 500
100
68
Get/Set
Not Used
UINT
Do not change the settings.
0 to 1000
100
69
Get/Set
Not Used
UINT
Do not change the settings.
0 to 1000
1000
70
Get/Set
Not Used
UINT
Do not change the settings.
0 to 1000
200
71
Get/Set
Not Used
UINT
Do not change the settings.
0 to 65535
32
72
Get/Set
Not Used
UINT
Do not change the settings.
0 to 65535
16
73
Get/Set
Not Used
UINT
Do not change the settings.
20 to 100
100
74
Get/Set
Not Used
UINT
Do not change the settings.
20 to 100
100
75
Get/Set
Not Used
UINT
Do not change the settings.
1 to 2000
50
76
Get/Set
Not Used
UINT
Do not change the settings.
1 to 2000
1000
77
Get/Set
Not Used
UINT
Do not change the settings.
1 to 150
50
78
Get/Set
Not Used
UINT
Do not change the settings.
1 to 150
70
79
Get/Set
Not Used
UINT
Do not change the settings.
0 to 150
100
80
Get/Set
Not Used
UINT
Do not change the settings.
0 to 150
100
81
Get/Set
Not Used
UINT
Do not change the settings.
0 to 2000
0
82
Get/Set
Not Used
UINT
Do not change the settings.
0 to 51200
0
83
Get/Set
Not Used
UINT
Do not change the settings.
10 to 250
50
84
Get/Set
Not Used
UINT
Do not change the settings.
0 to 250
0
85
Get/Set
Not Used
UINT
Do not change the settings.
0 to 100
0
(cont’d)
No.
Access
Name
Data Type
Description
Setting
Range
Default
Setting
Содержание OMNUC W R88A-NCW152-DRT
Страница 1: ...Cat No I538 E3 1 DeviceNet Option Unit OMNUC W Series Model R88A NCW152 DRT...
Страница 53: ...4 Connectors 4 5 3 DeviceNet Network Configuration Restrictions 4 22 4...
Страница 97: ...5 Parameter Settings 5 3 8 Notch Signal Output Positioning 5 44 5...
Страница 211: ...8 Servo Driver Settings 8 5 3 Absolute Encoder Multi turn Limit Setting 8 24 8...
Страница 257: ...9 Troubleshooting 9 46 9...