![background image](http://html1.mh-extra.com/html/omron/omnuc-w-r88a-ncw152-drt/omnuc-w-r88a-ncw152-drt_manual_743096219.webp)
9 Troubleshooting
9-8
9
A.05
A.05: Servomotor Mismatch
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
OFF
OFF
OFF
Cause
Remedy
A
The range of Servomotor capacities that can
be combined has been exceeded.
Replace the Servomotor so that a suitable
combination is achieved.
B
Encoder parameters have not been written
properly.
Replace the Servomotor.
At power ON
A, B