6 DeviceNet Communications
6.6.1 No-operation (Command Code: 0000, 0 Hex)
6-46
6
Station Command (Command Bit: STN = 1)
This section describes the Station Command function, related parameters, operation, and
command method.
Function
The Station Command can be used when the DeviceNet Unit is used in a rotating system.
One rotation of the Servomotor is divided into a specified number of stations and station
numbers are allocated.
When a station number is specified, the axis travels in the specified direction to the specified
position.
Related Parameters
The same speed and acceleration/deceleration data is used as for the Positioning Command.
Operation
Object
Attribute
No.
Name
Setting
Range
Unit
Effective
Timing
Default
Setting
Type
0x64
#32
Pn812
Coordinate Type
0, 1
−
Immediate
0
C
#33
Pn813
Command Unit/R
1 to 1,500,000
Steps
Immediate
360,000
C
#93
Pn853
Direction 0,
1
−
Immediate
0
B
#100
Pn85A Station
1 to 32, 767
−
Immediate
1
B
Speed
STN
1
0
DIR
1
0
Time