AC•THOR®9s Assembly Instructions, Version 200910                                    1

 

 

 

 

 

Assembly Instructions 

 

 

AC

THOR

®

9s 

Photovoltaic Power Manager  

 

Australian & New Zealand Distributor 

Energy Smart Water Pty Ltd   ABN 65 161 756 690    

A:

 2/11 Dalkeith Drive, Dromana Vic 3936, Australia 

W:

 esw.net.au  |  

P:

 +61 3 9939 6722  |  

E:

 [email protected]  

 

Содержание ESW AC-THOR 9s

Страница 1: ...0910 1 Assembly Instructions AC THOR 9s Photovoltaic Power Manager Australian New Zealand Distributor Energy Smart Water Pty Ltd ABN 65 161 756 690 A 2 11 Dalkeith Drive Dromana Vic 3936 Australia W esw net au P 61 3 9939 6722 E info esw net au ...

Страница 2: ...or two phases 13 7 2 Connecting temperature probes 13 8 Operation displays 14 9 Maintenance 14 10 Troubleshooting 15 11 Disposal 15 12 Warranty 15 12 1 Warranty General 15 12 2 Terms of Warranty 16 12 3 Warranty Exclusions 17 12 4 How to make a warranty claim 17 12 5 Purchaser s Statutory Rights 18 13 EU declaration of conformity 19 14 Technical specifications 20 15 Wiring diagrams 22 15 1 AC THOR...

Страница 3: ... or battery management 25 Control by the energy management system 26 15 2 AC THOR 9s Wiring applications 27 Operating mode M1 Hot water 9 kW 27 Operating mode M1 Hot water 3x 3 kW 28 Operating mode M2 Hot water stratification charge 29 Operating mode M4 Hot water heat pump 30 Operating mode M5 Hot water space heating 31 Operating mode M6 space heating 32 16 Installation Details Product Registratio...

Страница 4: ...on to these assembly instructions the current version of the Operating instructions for the device is available at www my pv com Wiring diagrams at the end of the document The following device key is required for online registration of the unit Keep it safe Enter device key here ...

Страница 5: ...idity must comply with the relevant regulations The ACTHOR has an ambient temperature rating of 0 C 40 C If installed outdoors it must be able to function within this temperature range and be located in a shaded position inside an IP55 rated waterproof cabinet which allows airflow around the unit Forced ventilation may need to be considered Contact techsupport esw net au for further advice regardi...

Страница 6: ...AC THOR 9s Assembly Instructions Version 200910 6 ...

Страница 7: ...s 6 mm my PV digital temperature sensor cable length 5 m with 8 pin plug Plug 5 pin for power supply Three plugs 3 pin for load outputs Plug 3 pin for 16 A switch output attached to the unit Operator stylus for the display with holder Assembly Instructions Key fob AC THOR Optional accessories available not included my PV Power Meter my PV digital temperature sensor cable length 5 m with 8 pin plug...

Страница 8: ...perated with phase and neutral conductor Never connect 400 V loads without neutral conductor Otherwise this may cause damage to the AC THOR 9s or to the other loads connected to it Only the supplied plugs must be used for connection to the AC THOR 9s Operation of heating systems incorporating electronic thermostats is not possible For heating water only heaters with an integral safety temperature ...

Страница 9: ... the housing must not be covered Avoid exposure to high temperatures 40 C low temperatures 0 C or direct sunlight during storage and operation The AC THOR 9s must be connected to a nominal voltage of 3 x 230 V AC 50 60 Hz The neutral conductor is necessary Protection of the mains connection for the AC THOR 9s may not exceed 16 A per phase tripping characteristic B or C 5 Connections overview ...

Страница 10: ...ll bracket to the wall with three screws Three screws and three wall plugs are supplied If the screws supplied are not suitable for the substrate suitable screw must be obtained 3 To fix it to the wall bracket the AC THOR 9s is suspended in the wall bracket by the two long slots on top and then fixed in place by locking it underneath slide to the left 4 Check the AC THOR 9s is securely fixed ...

Страница 11: ...witch cabinet door 6 A minimum lateral distance of 7cm must be observed 7 When installing several devices side by side a minimum distance of 10cm must be maintained 8 Then the electrical connections can be made Do not immerse my PV temperature sensor s directly in Water Use a thermowell For mains leads use a cable duct of 60 mm depth The cut out measures 130 x 60 mm ...

Страница 12: ...th clause 4 8 2 3 AS NZS 3000 2018 shall be installed for the water heater Where more than one circuit can supply the water heater a warning sign shall be installed within the installation switchboard that the solar diverter circuit originates and on the water heater NOTE The installation of a solar diverter can introduce an unforeseen hazard where if the grid supply to the water heater is isolate...

Страница 13: ...3 If the mains cable of the unit is damaged it must be replaced by the manufacturer or its service agents 7 2 Connecting temperature probes Up to four digital temperature probes three core bus system can be connected to the AC THOR 9s The terminal positions for the three cores are shown in the following illustration Phase L1 must be connected power supply Do not immerse my PV temperature sensor s ...

Страница 14: ...the graphic user interface the operating modes the menu guide and settings are located in the Operating Instructions for the unit The current version is available at www esw net au 9 Maintenance Do not attempt to open the AC THOR 9s The device does not contain any parts that may be repaired by the user In the event of a fault please contact Energy Smart Water on 1800 433 254 or email techsupport e...

Страница 15: ...ser In the event of a fault please contact Energy Smart Water on 1800 433 254 or email techsupport esw net au 11 Disposal Packaging material must be either stored or disposed of as appropriate Dispose of the AC THOR 9s at the end of its service life according to the statutory regulations 12 Warranty 12 1 Warranty General This warranty is given by Energy Smart Water Pty Ltd 2 11 Dalkeith Drive Drom...

Страница 16: ...ds municipal building codes occupational health safety welfare regulations and other State or Federal statutory regulations Where a failed product is replaced under this warranty the balance of the original warranty period will remain effective The replacement does not carry a new warranty This warranty extends to the original purchaser and subsequent owners but only while the product remains at t...

Страница 17: ...ted in a position that does not comply with the installation instructions or relevant statutory requirements Where the product is moved or reinstalled at a new location Where the connection attachment integration or general association of other equipment or parts not instructed by this manual which either directly or indirectly affect the performance or operation of this equipment Altering disasse...

Страница 18: ...eplaced in accordance with this warranty 12 5 Purchaser s Statutory Rights Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable qual...

Страница 19: ...ereby declares that the products of the product AC THOR 9s comply with the following Directives and standards EN 55014 1 EN 55014 2 EN 60730 1 EN 62233 EN 61000 3 2 EN 61000 3 3 The company named above holds available for inspection documentation as proof of fulfilment of the safety objectives and the principal safety requirements ...

Страница 20: ...to 3 000 W max or 230 V switched OUT 3 0 to 230 V pure sine 0 to 3 000 W max or 230 V switched Relay output 1 x UM 20 V AC 100 mA min 230 V AC 16 A max Mains connection 3 phase with neutral conductor Safeguarding 3 x 16 A tripping characteristic B C Load connection Plug contacts for resistive loads Standby consumption 2 W Efficiency 99 at rated power Operating temperature range 0 C to 40 C Permiss...

Страница 21: ...r my PV digital temperature sensor 5 m Display Colour graphic touch screen 2 83 Warranty 2 Years extended warranty upon request Weight without wall bracket 1 3 kg Dimension W x H x D 135 x 195 x 65 mm Interfaces Ethernet RJ45 RS485 potential free input PWM out PWM in Compatible systems see www my pv com ...

Страница 22: ... Assembly Instructions Version 200910 22 15 Wiring diagrams 15 1 AC THOR 9s Wiring the control side Power Meter connection via router Establishing the automatic connection via router may take as much as a minute ...

Страница 23: ...AC THOR 9s Assembly Instructions Version 200910 23 Power Meter connection without router ...

Страница 24: ...AC THOR 9s Assembly Instructions Version 200910 24 Power Meter connection without router via powerline ...

Страница 25: ...AC THOR 9s Assembly Instructions Version 200910 25 Control by inverter or battery management ...

Страница 26: ...AC THOR 9s Assembly Instructions Version 200910 26 Control by the energy management system ...

Страница 27: ...AC THOR 9s Assembly Instructions Version 200910 27 15 2 AC THOR 9s Wiring applications Operating mode M1 Hot water 9 kW ...

Страница 28: ...AC THOR 9s Assembly Instructions Version 200910 28 Operating mode M1 Hot water 3x 3 kW ...

Страница 29: ...AC THOR 9s Assembly Instructions Version 200910 29 Operating mode M2 Hot water stratification charge ...

Страница 30: ...AC THOR 9s Assembly Instructions Version 200910 30 Operating mode M4 Hot water heat pump ...

Страница 31: ...AC THOR 9s Assembly Instructions Version 200910 31 Operating mode M5 Hot water space heating ...

Страница 32: ...AC THOR 9s Assembly Instructions Version 200910 32 Operating mode M6 space heating ...

Страница 33: ...tallation Details Product Registration Name of licenced electrician Company Name Electrical license number Date of installation Signature of installer Certificate of Electrical Safety COES Visit Energy Smart Water to register your product www esw net au Notes ...