9.3 Troubleshooting with Alarm Displays
9-27
9
A.B2
A.B2: Torque Command Input Reading Error
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
A.B6
A.B6: Communications LSI Error
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
OFF
OFF
OFF
Cause
Remedy
A
Error in command read-in unit (A/D Con-
verter, etc.).
Reset alarm and restart operation.
B
Command read-in unit faulty (A/D Con-
verter, etc.).
Replace the Servo Driver.
C
Circuit board (1PWB) is defective.
Replace the Servo Driver.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
OFF
OFF
OFF
Cause
Remedy
A
The DeviceNet Unit is defective.
Replace the DeviceNet Unit.
C
A,
B
During
Servomotor
operation
At
power
ON
A
At power ON