9.3 Troubleshooting with Alarm Displays
9-13
9
A.41
A.41: Main Circuit DC Voltage Error Detected: Low Voltage
Display and Outputs
Note
OFF: Output transistor is OFF (alarm state). ON: Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
OFF
ON
OFF
Cause
Remedy
A
The power supply voltage is not within the
range of specifications.
Check power supply voltage.
B
Fuse blown.
Replace the Servo Driver.
C
Rectifying diode is defective.
D
The Servo Driver is defective.
D
A, B, C
A, B, C
During Servomotor
operation
Occurred when main
circuit power turned ON
Occurred when the control
circuit power turned ON