60
Service Manual – SW5500, FLOORTEC R 985
05 - Control System
Main Machine Controller (EB1) Connectors (Continues)
A1: Actuator 1 connection (main broom) (MOLEX MINIFIT type, 6-way vertical)
PIN
Description
Controller in/out
V ref.
I max.
Connected to
1
Main broom actuator /- ()
out
0/24V
8A
A1
2
ENGINE VERS. CONFIG. input
in
0V
<1A
A1.6
3
(Not used)
4
Main broom actuator supply -/+ (1)
out
0/24V
8A
A1
5
(Not used)
6
End-of-stroke microswitch power supply
out
0V
<1A
A1.2
A1
Figure 26:
A1
A2: Actuator 2 connection (RH side broom) (MOLEX MINIFIT type, 6-way vertical)
PIN
Description
Controller in/out
V ref.
I max.
Connected to
1
Right side broom actuator /- (1)
out
0/24V
8A
A2
2
(Not used)
3
(Not used)
4
Right side broom actuator supply -/+ (1)
out
0/24V
8A
A2
5
(Not used)
6
(Not used)
A2
Figure 27:
A2