281
Service Manual – SW5500, FLOORTEC R 985
52 - Hopper System
Lifted Hopper Sensor
Removal
1 Perform the points from 1 to 7 of the Closed Hopper Sensor procedure
2 Free up and disconnect the electrical connection (F) of the hopper lifted sensor (G)
3 Unscrew the nut (H) and remove the sensor (G) with wiring
Installation
4 Assemble the components in the reverse order of removal
Adjustment
5
Adjust the distance (I) between the sensor (G) and the flange (J) to 0,15-0,20 in (
4-5 mm), then tighten
the locknut (K) onto the nut (H)
Figure 13:
G
K
J
G
H
F
I