135
Service Manual – SW5500, FLOORTEC R 985
24 - Electrical System
Fuses
All circuits and components not managed directly by the Main Machine Controller (EB1) are protected by
fuses
Fuse
Battery
Diesel (YANMAR)
LPG (HONDA)
Pos.
Type
Value
Protected Function
Value
Protected Function
Value
Protected Function
F0
CABLE-PRO
-
125A
BATTERY FUSE
125A
BATTERY FUSE
F1
MIDI
150A
MAIN MACHINE
CONTROLLER
150A
MAIN MACHINE
CONTROLLER
150A
MAIN MACHINE
CONTROLLER
F2
UNIVAL
10A
KEY CIRCUIT
10A
KEY CIRCUIT
10A
KEY CIRCUIT
F3
MEGA
160A
DRIVE SYSTEM
BOARD
160A
DRIVE SYSTEM BOARD
150A
DRIVE SYSTEM BOARD
F4
MIDI
-
-
150A
BATTERY CHARGING
160A
BATTERY CHARGING
F5
CYL.
-
-
-
-
-
ALTERN. HONDA
F6
UNIVAL \ MIDI
-
-
100A
STARTER MOTOR
15A
START COMMAND
F7
UNIVAL
-
-
20A
ENGINE COMPARTMENT
FAN
20A
ENGINE COMPARTMENT
FAN
F8
UNIVAL
10A
HORN
10A
HORN
10A
HORN
The components managed directly by the Main Machine Controller (EB1) are protected by current reading
systems which switch off the component when specific maximum current draw values are exceeded for a
time greater than the set value
Main Machine Controller Alarm Code
Relays / Contactors
Description
Position
Manufacturer
Battery
Diesel
LPG
ES1
Main Machine Controller Contactor
Steering column
ALBRIGHT
X
X
X
ES2
Drive system contactor
Steering column
ALBRIGHT
X
X
X
ES3
Engine ON relay
LPG engine
TYCO
X
ES4
Engine speed relay
LPG engine
TYCO
X
ES5
Engine start relay
LPG Engine wiring
TYCO
X
ES6
Engine compartment fan relay
Main wiring
TYCO
X
X
ES7
Diesel engine power relay
Diesel Engine wiring
TYCO
X
ES8
Drive system enabling relay
Main wiring
TYCO
X
X
ES10
Charging system contactor
Main wiring
ALBRIGHT
X
X