43
Service Manual – SW5500, FLOORTEC R 985
05 - Control System
Machine Settings Screen (Continues)
The following parameters are displayed only when, on reaching the last RESET parameter, the hopper
lifting button
is pressed together with the One-Touch button
and the right side broom button
Otherwise, pressing only the hopper lifting button
returns to the first VSL parameter.
WARNING:
Do not change these parameters unless specifically to a factory representative.
HIDDEN PARAMETERS
Code
Description
Min.
value
Factory
Setting
Max.
value
Meaning
HYB
Hybrid system
NO
NO
YES
Set to YES if the machine is equipped with hybrid
system kit.
FAN
Altern./rpm/fan motor
management mode
NO
NO
YES
Technical parameter, do not modify.
TSERV
Service advisory timer
0
0
1,000
If > 0: number of hours before the “service” icon
appears on the multifunction display.
If = 0: function disabled.
ISC
Main broom
maximum current
Battery
50
70
1,000
Maximum continuous current permitted for the main
broom motor.
Diesel / LPG
50
60
100
HRC
Maximum number of hours
without recharge
0
5
50
(Significant only for machines equipped with hybrid
system KIT).
Cumulative number of hours running on battery without
performing a complete charge with on-board battery
charger.
AMAX
Maximum lateral acceleration
(g/100)
1
15
100
Maximum lateral acceleration value permitted without
reducing the machine speed.
KG
Lateral acceleration control
constant
1.0
1.6
2.0
Extent of speed reduction in the event the maximum
lateral acceleration threshold AMAX is exceeded. (High
value = greater speed reduction)
ASTAB
Maximum hopper safety angle
1
10
50
Maximum machine slope angle beyond which the
hopper dumping system is disabled for safety (hydraulic
pump supply voltage reduced to 50%).