Service Manual – SW5500, FLOORTEC R 985
50 - Dust Control System
Vacuum Fan Motor
Removal
1
Drive the machine on a level floor.
2 Lift the hopper to the end-of-stroke
WARNING: Place a safety rod under the lifted hopper..
3 Turn the ignition key to “0”, then engage the parking brake
4 Open the battery/engine compartment hood with the handle and fasten it with the support rod
5 Disconnect the battery connector (Battery Version) - Disconnect the batteries (Diesel and LPG Version)
6 Lift and remove the right side panel (A), disengaging it from the upper (B) and lower (C) fasteners
7
Disconnect the electrical connections (D) of the vacuum system electric fan and filter shaker.
8 Release the fasteners (E) of the vacuum system hood (F), without opening the hood itself
Figure 10:
A
C
B
E
E
F
B
C
C
B