185
Service Manual – SW5500, FLOORTEC R 985
29 - Engine System, LPG
Pressure Regulator
WARNING:
This procedure must be performed by personnel qualified to handle the LPG systems,
according to the law in force.
Moreover, it is necessary to wear accident-prevention clothes, according to the law in
force (heavy gloves, antistatic non-synthetic clothes, suitable to cover the whole body,
antistatic and antispark shoes, helmets with visor; etc.).
Removal
1
Drive the machine on a level floor.
in the relevant paragraph)
3 Turn the ignition key to “0”, then engage the parking brake
4 Open the engine compartment hood with the handle and fasten it with the support rod
5
If fitted, remove the machine right side panel by lifting it to disengage it from the fasteners.
6 If the engine is hot, wait that it cools down
7 Loosen the clamps (A) and disconnect the terminals (B) of the pressure regulator lines (C)
CAUTION:
For removal / installation of the various hoses and fittings of the LPG system, see
Figure 18:
A
B
A
C
B
D