176
Service Manual – SW5500, FLOORTEC R 985
29 - Engine System, LPG
Fuel Solenoid Valve Filter Cleaning
WARNING:
This procedure must be performed by personnel qualified to handle the LPG systems,
according to the law in force.
Moreover, it is necessary to wear accident-prevention clothes, according to the law in
force (heavy gloves, antistatic non-synthetic clothes, suitable to cover the whole body,
antistatic and antispark shoes, helmets with visor; etc.).
Disassembly
1 Remove the pressure regulator (see
in the relevant paragraph)
CAUTION:
For removal / installation of the various hoses and fittings of the LPG system, see
2
Unscrew the fitting (A) from the fuel solenoid valve on the workbench.
3
Remove the filter holder (B).
Inside the filter holder there is a cylinder with magnet (C) which will be cleaned and placed in the lower
side of the filter holder itself (as shown in the figure).
The filter holder gasket (D) must be replaced with the corresponding spare part, before reassembly.
Figure 11:
A
A
B
B
C
D