Service Manual – SW5500, FLOORTEC R 985
28 - Engine System, Diesel
Troubleshooting (continues)
Trouble
Possible causes
Remedy
The engine is overheating,
shutting down, and activating the
rectifier temperature sensor
Fan relay (ES6) faulty
Replace
Fan fuse (F7) blown
Replace
Fan (M7) faulty
Replace
The engine loses power or stops
during operation.
The filter element or elements are clogged
Clean or replace the filter elements
The fuel filter is clogged, the start system is broken,
the valves are locked, etc.
Replace or repair the faulty components as
necessary (take the engine to an authorized
Honda service centre)
The machine shuts down
Battery fuse (F0) blown
Replace
The machine generates an alarm
when powered (see
)
Alternator fuse (F4) blown
Replace
Charging system contactor (ES10) faulty
Replace