280
Service Manual – SW5500, FLOORTEC R 985
52 - Hopper System
Closed Hopper Sensor (Continues)
8 Free up and disconnect the electrical connection (F) of the hopper closed sensor (G)
9 Unscrew the nut (H) and remove the sensor (G) with wiring
Installation
10 Assemble the components in the reverse order of removal
Adjustment
11
Adjust the distance (I) between the sensor (G) and the flange (J) to 0,15-0,20 in (
4-5 mm), then tighten
the locknut (K) onto the nut (H)
Figure 12:
G
K
J
H
F
I
G