140
Service Manual – SW5500, FLOORTEC R 985
24 - Electrical System
Troubleshooting
Trouble
Possible causes
Remedy
The machine is not working
The batteries (BAT) are discharged or its
connections are not efficient
Charge the batteries or clean/repair the
connections
The batteries (BAT) are broken
Check the battery no-load voltage/replace them
(Battery Version)
Battery charger (CH) faulty
Replace
(Diesel and LPG Versions)
Alternator (ALT) faulty
Repair/replace
The fuses are open
Replace
The wiring harness is cut or pressed or short
circuited
Repair
The ignition key switch (KEY) is not working
Replace
Main Machine Controller (EB1) broken
Replace