42
Service Manual – SW5500, FLOORTEC R 985
05 - Control System
Machine Settings Screen
The machine settings screen functions allow you to customize some parameters described in the following
table of modifiable parameters.
Figure 8:
1 To increase the value of the current parameter, press the increase running speed button
2 To decrease the value of the current parameter, press the decrease running speed button
3 To move to the next parameter, press the hopper lifting button
4 To return to the main screen, press and hold the hopper lowering button
MODIFIABLE PARAMETERS
Code
Description
Min. value
Factory Setting
Max. value
VSL
Side broom speed
50%
100%
100%
SCF
Filter shaker activation time
5 sec
20 sec
60 sec.
FVMIN
Minimum forward speed
0%
25%
100%
FVMAX
Maximum forward speed
Battery
10%
85%
100%
Diesel / LPG
10%
100%
100%
RVMAX
Maximum reverse speed
10%
30%
50%
BAT (*)
Installed battery type
WET
WET
GEL / AGM
TOFF
Automatic shut-off time
0 sec
300 sec
600 sec
BRGH
Display contrast
5
25
50
RESET (**)
Resets all parameters to the factory default values
NO
NO
YES
(*)
Significant for version and battery and with hybrid kit installed.
(**) The RESET function is active only for “MODIFIABLE PARAMETERS” and not for “HIDDEN PARAM-
ETERS”