O P E r a T i O N
oP
neSS D24 Control Panel - inStallation & PrograMMing Manual
oPerAtINg moDeS
the ness D24 will operate in one of the following modes:
ArmeD:
the system is “on” and ready to detect intrusion. 24 hour Zones (if
configured) are still active. area Partitioning means the panel can be split into three
separate “areas” which can be armed and Disarmed independently of each other.
DISArmeD:
the system is “off”. this is the normal mode when the premises are
occupied. Day Zones and 24 hour Zones (if configured) are still active.
DAY mode:
the system is
Disarmed
and a zone or zones have been setup to create
an alarm when activated. often used as a doorway alert in a shop.
moNItor mode:
allows the system to be “partially” armed. For example, in a
house, to allow all perimeter zones, doors and windows, to be Monitored (armed)
at night.
24Hr Zones:
Zones that have been setup to be active in any mode. usually used
for tamper switches and Panic buttons.
armiNg THE SySTEm
if the D24 has not been programmed for area operation, this method will arm the
entire system.
Press...
(If Two Button Keypad Operation is disabled. This is the factory default.)
...or
(If Two Button Keypad Operation is enabled.)
...or
[COde]
(If Shortcut Arming is disabled.)
Three beeps will sound
and the ARM icon will turn ON
ARM
leave the premises within the exit Delay time.
at the end of exit Delay time, 1 beep will sound
diSarmiNg THE SySTEm
if the D24 has not been programmed for area operation, this method will Disarm
the entire system.
Press...
[COde]
Three beeps will sound
and the ARM icon will turn OFF
ARM
Disarm the panel during the entry Delay time to prevent unwanted “alarm on
entry”.
sIren warnIng:
At the end of the exit time, all zones should
be
sealed
. If any are
unsealed
, the siren
will sound for 2 seconds as a warning
to indicate that those zones have been
automatically excluded. For maximum
security, you should return, Disarm, check
the premises and then Arm again. Continual
warnings could mean that a detector
is faulty and may have to be manually
excluded.
autO eXClude:
If the auto-exclude option is disabled, the
siren will sound for the duration of reset
time if a zone is Unsealed at the end of exit
time.
errOr Beep when dIsarMIng:
An error beep when attempting to Disarm
may indicate:
• Incorrect Code
• or the panel is already Disarmed
• or the panel is in Exclude mode